C1112 (bizhub C360i/C300i/C250i)
Contents
Trouble type | C1112: Stapler motor malfunction | |
Rank | B | |
Trouble detection condition | <When FS-536SD is installed> • The stapler home sensor is not turned ON even after the set period of time has elapsed while the stapler motor is energized. • The stapler home sensor is not turned OFF even after the set period of time has elapsed after the stapler home sensor is turned ON. | |
Trouble isolation | • Staple • Center Stapling/Half-Fold/Tri-Fold | |
Relevant electrical parts | <When FS-536SD is installed> • Staple unit • SD control board (SDCB) • FS control board (FSCB) |
Procedure
- Check the connector between the staple unit-SDCB J4 for proper connection and correct as necessary.
- Check the connector of the staple unit for proper drive coupling and correct as necessary.
- Replace the staple unit.
- Replace SDCB. (Part# A3EP560100)
- Replace FSCB. (Part# A87GPP0V00)
Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.
L.3.7.8 (Link to the Field Service Manual)