C1112 (bizhub C364/C284/C224)
Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.
Contents
Trouble type | Stapler motors malfunction | |
Trouble code | C1112 | |
Rank | B | |
Detection timing | <When FS-534+SD-511 is installed> -The stapler home sensor is not turned ON even after the set period of time has elapsed while the stapler motor is energized. -The stapler home sensor is not turned OFF even after the set period of time has elapsed after the stapler home sensor is turned ON. | |
Trouble isolation | -Staple -Half-Fold/Tri-Fold Center Stapling | |
Relevant electrical parts | -Staple unit -SD drive board (SDDB) -FS control board (FSCB) |
(2)Procedure
Step | Action | Control signal | Location of electrical components |
1 | Check the connector between the staple unit-SDDB J4 for proper connection and correct as necessary. | – | – |
2 | Check the connector of the staple unit for proper drive coupling and correct as necessary. | – | – |
3 | Replace the staple unit (Part# A3ER929300) | – | – |
4 | Replace SDDB (Part# A3ERPP6J03) | – | – |
5 | Replace FSCB (Part# A3EPPPBE01) | – | – |
- Link to the layout drawings for related parts by each trouble code (S.20. C1112)
K3.6.8 (Link to the Field Service Manual)