C1124 (bizhub 754e/654e)

You are here:

Contents

Trouble typeSheet feeder up/down drive failure (lower)
Trouble codeC1124
RankB
Detection timing<When FS-535+PI-505 is installed>
The tray upper limit sensor /Lw (PS209) or tray lower limit sensor /Lw (PS210) are not turned ON even after the set period of time has elapsed after the tray lift motor /Lw (M202) is energized.
Trouble isolationPost Inserter
Relevant electrical parts• Tray lift motor /Lw (M202)
• Tray upper limit sensor /Lw (PS209)
• Tray lower limit sensor /Lw (PS210)
• PI drive board (PIDB)
• FS control board (FSCB)

 (2)Procedure

StepActionControl signalLocation of electrical components
1Check the connector between M202-relay CN206-PIDB CN56 for proper connection, and correct as necessary.
2Check the connector of M202 for proper drive coupling, and correct as necessary.
3Check the connector between PS209-relay CN237-PIDB CN53<A> for proper connection, and correct as necessary.
4Check the connector between PS210-relay CN236-PIDB CN53<A> for proper connection, and correct as necessary.
5PS209 I/O check, sensor checkPIDB CN53<A>-8 (ON)PI-505 8-C to D
6PS210 I/O check, sensor checkPIDB CN53<A>-11 (ON)PI-505 9-C to D
7M202 operation checkPIDB CN56-5 to 6PI-505 7-C to D
8Replace M202 (Part# A10YA6560 )
9PIDB ICP2 conduction check
10Replace PIDB (Part# A10AH01001 )
11Replace FSCB (Part# A2Y1H10002 )

Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.

(Link to the Field Service Manual) K.3.6.16