C1125 (bizhub 754e/654e)

You are here:

Contents

Trouble typeSheet feeder up/down drive failure (upper)
Trouble codeC1125
RankB
Detection timing<When FS-535+PI-505 is installed>
The tray lower limit sensor /Up (PS205) or tray upper limit sensor /Up (PS204) are not turned ON even after the set period of time has elapsed after the tray lift motor /Up (M201) is energized.
Trouble isolationPost Inserter
Relevant electrical parts• Tray lift motor /Up (M201)
• Tray upper limit sensor /Up (PS204)
• Tray lower limit sensor /Up (PS205)
• PI drive board (PIDB)
• FS control board (FSCB)

 (2)Procedure

StepActionControl signalLocation of electrical components
1Check the connector between M201-relay CN203-PIDB CN54 for proper connection, and correct as necessary.
2Check the connector of M201 for proper drive coupling, and correct as necessary.
3Check the connector between PS204-relay CN235-PIDB CN55 for proper connection, and correct as necessary.
4Check the connector between PS205-relay CN235-PIDB CN55 for proper connection, and correct as necessary.
5PS204 I/O check, sensor checkPIDB CN55-8 (ON)PI-505 5-C to D
6PS205 I/O check, sensor checkPIDB CN55-7 (ON)PI-505 6-C to D
7M201 operation checkPIDB CN54-7 to 8PI-505 4-C to D
8Replace M201 (Part# A10YA6560 )
9PIDB ICP2 conduction check
10Replace PIDB (Part# A10AH01001 )
11Replace FSCB (Part# A2Y1H10002 )

Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.

(Link to the Field Service Manual) K.3.6.17