How Can We Help?

C1127 (bizhub 754e/654e)

You are here:

Contents

Trouble typePunch oscillating motor’s drive malfunction
Trouble codeC1127
RankB
Detection timing<When FS-535+PK-521 is installed>
The PK punch home sensor (PS303) is not turned ON even after the set period of time has elapsed while the punch oscillating motor (M302) is energized.
Trouble isolationPunch
Relevant electrical parts• Punch oscillating motor (M302)
• PK punch home sensor (PS303)
• Punch control board (PKCB)
• FS control board (FSCB)

 (2)Procedure

StepActionControl signalLocation of electrical components
1Check the connector between M302-relay CN342-relay CN341-PKCB CN37 for proper connection, and correct as necessary.
2Check the connector of M302 for proper drive coupling, and correct as necessary.
3Check the connector between PS303-relay CN342-relay CN341-PKCB CN34 for proper connection, and correct as necessary.
4PS303 I/O check, sensor checkPKCB CN37-2 (ON)PK-521 5-C
5M302 operation checkPKCB CN34-1 to 6PK-521 5-C
6Replace M302 (Part# A11TM10100 )
7Replace PKCB (Part# A2YRH10103 )
8Replace FSCB (Part# A2Y1H10002 )

Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.

(Link to the Field Service Manual) K.3.6.18

Table of Contents