Trouble type1st stopper motor’s drive malfunction
Trouble codeC1130
RankB
Detection timing<When FS-535+ZU-606 is installed>
The 1st folding stopper home sensor (PS603) is not turned ON even after the set period of time has elapsed after the 1st stopper motor (M602) starts searching home position.
Trouble isolationZ fold
Relevant electrical parts• 1st stopper motor (M602)
• 1st folding stopper home sensor (PS603)
• ZU control board (ZUCB)

 (2)Procedure

StepActionControl signalLocation of electrical components
1Check the connector between M602-relay CN30-ZUCB CN15 for proper connection, and correct as necessary.
2Check the connector of M602 for proper drive coupling, and correct as necessary.
3Check the connector between PS603-relay CN636-ZUCB CN4 for proper connection, and correct as necessary.
4PS603 I/O check, sensor checkZUCB CN4-11 (ON)ZU-606 5-C
5M602 operation checkZUCB CN15-4 to 6ZU-606 3-C
6Replace M602 (Part# 13GQ80032 )
7ZUCB ICP7 conduction check
8Replace ZUCB (Part# A109H01002 )