How Can We Help?

C1125 (bizhub 958/808)

You are here:

Contents

Trouble typeC1125: Tray lift motor /Up’s drive malfunction
RankB
Trouble detection condition<When FS-537+PI-507 or FS-537SD+PI-507 is installed>
The tray upper limit sensor /Up (PS205) or tray lower limit sensor /Up (PS204) is not turned ON (blocked) after the set period of time has elapsed after the tray lift motor /Up (M201) is turned ON.
Problem Unit Isolation Set.Post inserter
Relevant electrical parts• Tray lift motor /Up (M201)
• Tray upper limit sensor /Up (PS204)
• Tray lower limit sensor /Up(PS205)
• PI drive board (PIDB)
• FS control board (FSCB)

 Procedure

  1. Check the connector between M201-relay CN203-PIDB CN54 for proper connection and correct as necessary.
  2. Check the connector of M201 for proper drive coupling and correct as necessary.
  3. Check the connector between PS204-relay CN235-PIDB CN55 for proper connection and correct as necessary.
  4. Check the connector between PS205-relay CN235-PIDB CN55 for proper connection and correct as necessary.
  5. PS204 I/O check, sensor check
    • Control signal: PIDB CN55-8 (ON)
    • Location of electrical component: PI-507 8-C
  6. PS205 I/O check, sensor check
    • Control signal: PIDB CN55-7 (ON)
    • Location of electrical component: PI-507 8-C
  7. M201 operation check
    • Control signal: PIDB CN54-7 to 8
    • Location of electrical component: PI-507 6 to 7-C
  8. Replace M201. (Part# A5C1M10A00)
  9. Replace PIDB. (Part# A8C6H00101)
  10. Replace FSCB. (Part# A87HPP9M01)

NOTICE

  • Link to the wiring diagram (PI-507)

Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.

K.3.7.16 (Link to the Field Service Manual)

Table of Contents