C1127 (bizhub 958/808)
Trouble type | C1127: Punch oscillating motors drive malfunction | |
Rank | B | |
Trouble detection condition | <When FS-537+PK-523 or FS-537SD+PK-523 is installed> The PKpunch oscillatinghome sensor (PS303) is not turned ON (blocked) or OFF (unblocked) even after the set period of time has elapsed while the punch oscillating motor (M302) is energized. | |
Problem Unit Isolation Set. | Punch | |
Relevant electrical parts | • Punch oscillating motor (M302) • PK punch oscillatinghome sensor (PS303) • Punch control board (PKCB) • FS control board (FSCB) |
Procedure
- Check the connector between M302-relay CN342-relay CN341-PKCB CN1 for proper connection and correct as necessary.
- Check the connector of M302 for proper drive coupling and correct as necessary.
- Check the connector between PS303-relay CN342-relay CN341-PKCB CN37 for proper connection and correct as necessary.
- PS303 I/O check, sensor check
- Control signal: PKCB CN37-2 (ON)
- Location of electrical component: PK-523 5-C
- M302 operation check
- Control signal: PKCB CN1-1 to 6
- Location of electrical component: PK-523 5-C
- Replace M302. (Part# A11TM10100)
- PKCB ICP2 conduction check.
- Replace PKCB. (Part# A99KH00103)
- Replace FSCB. (Part# A87HPP9M01)
NOTICE
- Link to the wiring diagram (PK-523)
Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.
K.3.7.17 (Link to the Field Service Manual)