How Can We Help?

C1132 (bizhub C754e/C654e)

You are here:

Contents

Trouble typePunch drive motor’s malfunction
Trouble codeC1132
RankB
Detection timing<When FS-534+PK-520 is installed>
The punch home sensor (PS1) is not blocked or unblocked even after the set period of time has elapsed while the punch drive motor (M1) is energized.
<When FS-535+PK-521 is installed>
The PK punch home sensor/2 (PS301) is not blocked or unblocked even after the set period of time has elapsed while the punch drive motor (M301) is energized.
Trouble isolation
Relevant electrical parts<When FS-534+PK-520 is installed>
• Punch drive motor (M1)
• Punch home sensor (PS1)
• FS control board (FSCB)
<When FS-535+PK-521 is installed>
• Punch drive motor (M301)
• PK punch home sensor/2 (PS301)
• Punch control board (PKCB)
• FS control board (FSCB)

 (2)ProcedureWhen FS-534+PK-520 is installed

StepActionControl signalLocation of electrical components
1Check the connector between M1-relay CN351-FSCB J7 for proper connection, and correct as necessary.
2Check the connector of M1 for proper drive coupling, and correct as necessary.
3Check the connector between PS1-FSCB J7 for proper connection, and correct as necessary.
4PS1 I/O check, sensor checkFSCB J7-5 (ON)FS-534 (PK-520) 7-K
5M1 operation checkFSCB J7-7 to 8FS-534 (PK-520) 7-K
6Replace M1 (Part# A4JUF93100 Punch Unit/2 / Part# A4JUF93200 Punch Unit/3)
7Replace FSCB (Part# A3EPPPBE01)

When FS-535+PK-521 is installed

StepActionControl signalLocation of electrical components
1Check the connector between M301-relay CN351-PKCB CN35 for proper connection, and correct as necessary.
2Check the connector of M301 for proper drive coupling, and correct as necessary.
3Check the connector between PS301-PKCB CN36 for proper connection, and correct as necessary.
4PS301 I/O check, sensor checkPKCB CN36-5 (ON)PK-521 3-C
5M301 operation checkPKCB CN35-1 to 3PK-521 2-C
6Replace M301 (Part# A4JUR70400 Punch Unit /1 / Part# A4JUR70500 Punch Unit /2 / Part# A4JUR70600 Punch Unit /3)
7Replace PKCB (Part# A2YRH10103)
8Replace FSCB (Part# A2Y1H10002)