How Can We Help?

C1133 (bizhub C754e/C654e)

You are here:

Contents

Trouble typePunch shift motor’s drive malfunction
Trouble codeC1133
RankB
Detection timing<When FS-535+ZU-606 is installed>
The punch shift home sensor (PS605) is not turned ON, or is not turned OFF after it is turned ON, even after the set period of time has elapsed after the punch shift motor (M605) starts searching its home position.
Trouble isolationZ fold
Relevant electrical parts• Punch shift motor (M605)
• Punch shift home sensor (PS605)
• ZU control board (ZUCB)

 (2)Procedure

StepActionControl signalLocation of electrical components
1Check the connector between M605-ZUCB CN5 for proper connection, and correct as necessary.
2Check the connector of M605 for proper drive coupling, and correct as necessary.
3Check the connector between PS605-ZUCB CN3 for proper connection, and correct as necessary.
4PS605 I/O check, sensor checkZUCB CN3-2 (ON)ZU-606 6-C
5M605 operation checkZUCB CN5-1 to 6ZU-606 2-C
6Replace M605 (Part# 56GA80062)
7ZUCB ICP5 conduction check
8Replace ZUCB (Part# A109H01002)

Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.

K.3.6.22 (Link to the Field Service Manual)

Table of Contents