Trouble typeMain motor cooling fan’s drive malfunction
Trouble codeC1134
RankB
Detection timing<When FS-535+ZU-606 is installed>
Even after the set period of time has elapsed after the main motor cooling fan (FM601) is turned ON, the FM601 EM signal is faulty and the fan is turned OFF; the signal is faulty after each of the following three trials.
Trouble isolation
Relevant electrical parts• Main motor cooling fan (FM601)
• ZU control board (ZUCB)

 (2)Procedure

StepActionControl signalLocation of electrical components
1Check the connector between FM601-relay CN653-ZUCB CN11 for proper connection, and correct as necessary.
2Check the connector of FM601 for proper drive coupling, and correct as necessary.
3FM601 operation checkZUCB CN11-11 (DRV)ZU-606 8 to 9-C
4Replace FM601 (Part# 27LA80511)
5ZUCB ICP8 conduction check
6Replace ZUCB (Part# A109H01002)

Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.