(1)Contents

Trouble typePunch switchover motors drive malfunction
Trouble codeC1136
RankB
Detection timing<When FS-535+ZU-606 is installed>
The punch switchover switch (MS601) is not turned OFF from the ON position, or not turned ON from the OFF position, even after the set period of time has elapsed after the punch switchover motor (M608) is turned ON.
Trouble isolationZ fold
Relevant electrical parts• Punch switchover motor (M608)
• Punch switchover switch (MS601)
• ZU control board (ZUCB)

 (2)Procedure

StepActionControl signalLocation of electrical components
1Check the connector between M608-relay CN633-relay CN638-ZUCB CN11 for proper connection, and correct as necessary.
2Check the connector of M608 for proper drive coupling, and correct as necessary.
3MS601 I/O check, sensor checkZUCB CN11-9ZU-606 8-C
4M608 operation checkZUCB CN11-8 (DRV)ZU-606 7 to 8-C
5Replace M608 (Part# 14JB50012E)
6ZUCB ICP9 conduction check
7Replace ZUCB (Part# A109H01002)
  • Link to the wiring diagram (N.3.14 ZU-606)
  • Link to the layout drawings for related parts by each trouble code (S.38. C1136)

Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.

K.3.6.25 (Link to the Field Service Manual)