Trouble typeAlignment plate motor/Rrs malfunction
Trouble codeC1140
RankB
Detection timing<When FS-533 is installed>
• The alignment plate home sensor/R (PS109) is not unblocked after the set period of time has elapsed after the plate drive starts from the home position.
• The alignment plate home sensor/R (PS109) is not blocked after the set period of time has elapsed when the plate returns to the home position.

<When FS-534 is installed>
The alignment plate/R home sensor (PS13) is not blocked or unblocked even after the set period of time has elapsed while the alignment motor/Rr (M8) is energized.

<When FS-535 is installed>
The alignment plate motor home sensor/Rr (PS18) is not blocked even after the set period of time has elapsed while the alignment plate motor/Rr (M12) is energized.
Trouble isolation
Relevant electrical parts<When FS-533 is installed>
• Alignment motor/R (M106)
• Alignment plate home sensor/R (PS109)
• FS control board (FSCB)

<When FS-534 is installed>
• Alignment motor/Rear (M8)
• Alignment plate/R home sensor (PS13)
• FS control board (FSCB)

<When FS-535 is installed>
• Alignment plate motor/Rr (M12)
• Alignment plate motor home sensor/Rr (PS18)
• FS control board (FSCB)

 (2)ProcedureWhen FS-533 is installed

StepActionControl signalLocation of electrical components
1Check the connector between M106-FSCB CN102 for proper connection and correct as necessary.
2Check the connector of M106 for proper drive coupling and correct as necessary.
3Check the connector between PS109-relay CN106-FSCB CN102 for proper connection and correct as necessary.
4PS109 I/O check, sensor checkFSCB CN102FS-533 7-J
5M106 operation checkFSCB CN102FS-533 8-J
6Replace M106 (Part# A3EPPP5500)
7FSCB CP105 conduction check
8Replace FSCB (Part# A2YUPPH901(Model No. A2YU-WY1) or A2YUPPXN00 (Model No. A2YU-WY2))

When FS-534 is installed

StepActionControl signalLocation of electrical components
1Check the connector between M8-FSCB J12 for proper connection, and correct as necessary.
2Check the connector of M8 for proper drive coupling, and correct as necessary.
3Check the connector between PS13-FSCB J9 for proper connection, and correct as necessary.
4PS13 I/O check, sensor checkFSCB J9<B>-9 (ON)FS-534 9-C
5M8 operation checkFSCB J12-13 to 16FS-534 5 to 6-C to D
6Replace M8 (Part#A2Y1R70200)
7Replace FSCB (Part# A3EPPPBE01)

When FS-535 is installed

StepActionControl signalLocation of electrical components
1Check the connector between M12-FSCB CN19 for proper connection, and correct as necessary.
2Check the connector of M12 for proper drive coupling, and correct as necessary.
3Check the connector between PS18-FSCB CN20 for proper connection, and correct as necessary.
4PS18 I/O check, sensor checkFSCB CN20-3 (ON)FS-535 11-D
5M12 operation checkFSCB CN19-5 to 8FS-535 10-D
6Replace M12 (Part#A2Y1R70200)
7Replace FSCB (Part# A2Y1H10002)

Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.

K.3.6.26 (Link to the Field Service Manual)

Table of Contents