How Can We Help?

C1145 (bizhub C360i/C300i/C250i)

You are here:

Contents

Trouble typeC1145: Trailing edge stopper motor malfunction
RankB
Trouble detection condition<When FS-536 or FS-536SD is installed>
The trailing edge stopper home position detection sensor (PS20) is not turned OFF (unblocked) or ON (blocked) even after the set period of time has elapsed after the trailing edge stopper motor (M6) is turned ON.
Trouble isolationStaple
Relevant electrical parts<When FS-536 or FS-536SD is installed>
• Trailing edge stopper motor (M6)
• Trailing edge stopper home position detection sensor (PS20)
• FS control board (FSCB)

Procedure

  1. Check the connector between M6-FSCB J5 for proper connection and correct as necessary.
  2. Check the connector of M6 for proper drive coupling and correct as necessary.
  3. Check the connector between PS20-relay CN19-FSCB J5 for proper connection and correct as necessary.
  4. PS20 I/O check, sensor check
    • Control signal: FSCB J5-9 (ON)
    • Location of electrical component: FS-536/FS-536SD 15-K
  5. M6 operation check
    • Control signal: FSCB J5-13 to 16
    • Location of electrical component: FS-536/FS-536SD 15-K
  6. Replace M6. (Part# A3EPPP5500)
  7. Replace FSCB. (Part# A87GPP0V00)

Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.