C1145 (bizhub C364e/C284e/C224e)
Contents
Trouble type | Trailing edge stopper motor’s malfunction | |
Trouble code | C1145 | |
Rank | B | |
Detection timing | <When FS-534 is installed> The trailing edge stopper home position detection sensor (PS20) is not blocked or unblocked even after the set period of time has elapsed after the trailing edge stopper motor (M6) is turned ON. | |
Trouble isolation | – | |
Relevant electrical parts | • Trailing edge stopper motor (M6) • Trailing edge stopper home position detection sensor (PS20) • FS control board (FSCB) |
(2)Procedure
Step | Action | Control signal | Location of electrical components |
1 | Check the connector between M6-FSCB J5 for proper connection, and correct as necessary. | – | – |
2 | Check the connector of M6 for proper drive coupling, and correct as necessary. | – | – |
3 | Check the connector between PS20-relay CN22-FSCB J5 for proper connection, and correct as necessary. | – | – |
4 | PS20 I/O check, sensor check | FSCB J5-9 (ON) | FS-534 9-K |
5 | M6 operation check | FSCB J5-13 to 16 | FS-534 9-K |
6 | Replace M6 (Part# A3EPPP5500) | – | – |
7 | Replace FSCB (Part# A3EPPPBE01) | – | – |
- Link to the wiring diagram (N.2.7 FS-534)
- Link to the layout drawings for related parts by each trouble code (S.28. C1145)
Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.
K.3.6.16 (Link to the Field Service Manual)