Trouble typeExit roller pressure/ retraction malfunction <When FS-533 is installed>
Trouble codeC11A1
RankB
Detection timing<When FS-533 is installed>
The pick up roller position sensor (PS105) is turned neither ON nor OFF even after the set period of time has elapsed after the exit roller lift up motor (M104) is turned ON.
Trouble isolation
Relevant electrical parts-Exit roller lift up motor (M104)
-Pick up roller position sensor (PS105)
-FS control board (FSCB)

(2)Procedure

StepActionControl signalLocation of electrical components
1Check the connector between M104-FSCB CN109 for proper connection and correct as necessary.
2Check the connector of M104 for proper drive coupling, and correct as necessary.
3Check the connector between PS105-FSCB CN110 for proper connection and correct as necessary.
4PS105 I/O check, sensor checkFSCB CN110FS-533 7-D to E
5M104 operation checkFSCB CN109FS-533 9-D to E
6Replace M104 (Part# A2YUPPW400)
7FSCB CP104 conduction check
8Replace FSCB (Part# A2YUPPH901(Model No. A2YU-WY1) or A2YUPPXN00 (Model No. A2YU-WY2))
  • Link to the wiring diagram (N.3.7 FS-533)
  • Link to the layout drawings for related parts by each trouble code (S.52. C11A1)

K3.6.39 (Link to the Field Service Manual)