Trouble type | Accommodation roller pressure/ retraction malfunction | |
Trouble code | C11A2 | |
Rank | B | |
Detection timing | <When FS-534 is installed> The receiving roller retraction sensor (PS11) is not blocked or unblocked even after the set period of time has elapsed after the receiving roller retraction motor (M4) is turned ON. | |
Trouble isolation | Half-Fold/Tri-Fold Center Stapling | |
Relevant electrical parts | -Receiving roller retraction motor (M4) -Receiving roller retraction sensor (PS11) -FS control board (FSCB) |
(2)Procedure
Step | Action | Control signal | Location of electrical components |
1 | Check the connector between M4-FSCB J4 for proper connection and correct as necessary. | – | – |
2 | Check the connector of M4 for proper drive coupling, and correct as necessary. | – | – |
3 | Check the connector between PS11-FSCB J4 for proper connection, and correct as necessary. | – | – |
4 | PS11 I/O check, sensor check | FSCB J4<B>-16 (ON) | FS-534 13-C |
5 | M4 operation check | FSCB J4<A>-1 to 4 | FS-534 11-C to D |
6 | Replace M4 (Part# A3EPPP5600) | – | – |
7 | Replace FSCB (Part# A3EPPPBE01) | – | – |
- Link to the wiring diagram (N.3.8 FS-534)