How Can We Help?

C2101 (bizhub 958/808)

You are here:

Contents

Trouble typeC2101: Charge cleaning motor/K malfunction
RankB
Trouble detection conditionDuring backward and return movement of the cleaner material, the charging cleaner home sensor (PS43) is not turned OFF (unblocked) after a predetermined period of time has elapsed.
Trouble isolation
Relevant electrical parts• Drum unit
• Charging cleaner home sensor (PS43)
• Charging cleaner return sensor (PS44)
• Charge cleaning motor/K (M15)
• PH relay board (PHRYB)
• MFP board (MFPB)

 Procedure

  1. Check the drum unit for proper connection and correct as necessary.
  2. Check the connector between M15-PHRYB CN4 for proper connection and correct as necessary.
  3. Check the connector of M15 for proper drive coupling and correct as necessary.
  4. Check the connector between PS43-PHRYB CN6 for proper connection and correct as necessary.
  5. Check the connector between PS44-PHRYB CN6 for proper connection and correct as necessary.
  6. PS43 I/O check, sensor check
    • Control signal: PHRYB CN6-5 (ON)
    • Location of electrical component: 3-B
  7. PS44 I/O check, sensor check
    • Control signal: PHRYB CN6-8 (ON)
    • Location of electrical component: 4-B
  8. M15 operation check
    • Control signal: PHRYB CN4-1 to 2
    • Location of electrical component: 5-B, 6-B
  9. Replace the drum unit. (Part# A8H40RD)
  10. Replace M15. (Part# A0P0R75200)
  11. PHRYB F2 conduction check.
  12. Replace PHRYB. (Part# A796H00300)
  13. Replace MFPB. (Part# A796H02003)

NOTICE

Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.

K.3.8.1 (Link to the Field Service Manual)

Table of Contents