C2151 (bizhub 958/808)
Contents
Trouble type | C2151: Transfer roller pressure welding alienation |
Rank | B |
Trouble detection condition | • The 2nd transfer pressure sensor (PS50) does not turn OFF (unblock) (retracting) even after the lapse of a given period of time after the 2nd transfer pressure motor (M3) has started rotating during the 2nd image transfer roller is retracting. • The 2nd transfer pressure sensor (PS50) does not ON (block) (pressuring) even after the lapse of a given period of time after the 2nd transfer pressure motor (M3) has started rotating during the 2nd image transfer roller is pressuring. |
Trouble isolation | – |
Relevant electrical parts | • 2nd transfer pressure motor (M3) • 2nd transfer pressure sensor (PS50) • Paper feed/transport drive board (PFTDB) • MFP board (MFPB) |
Procedure
- Check the connector between M3-relay CN271B-PFTDB CN8 for proper connection and correct as necessary.
- Check the connector of M3 for proper drive coupling and correct as necessary.
- Check the connector between PS50-relay CN271A-PFTDB CN2 for proper connection and correct as necessary.
- PS50 I/O check, sensor check
- Control signal: PFTDB CN2-9 (ON)
- Location of electrical component: 5-P
- M3 operation check
- Control signal: PFTDB CN8-1 (REM)
- Location of electrical component: 6-P
- Replace M3. (Part # A0P0R75400)
- PFTDB F17 conduction check
- Replace PFTDB. (Part# A796H00200)
- Replace MFPB. (Part# A796H02003)
NOTICE
- Link to the wiring diagram (bizhub 958/808/758, bizhub PRO 958)
Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.
K.3.8.2 (Link to the Field Service Manual)