C2151 (bizhub C754/C654)

You are here:

Contents

Trouble typeSecondary transfer roller pressure welding alienation
Trouble codeC2151
RankB
Detection timing-The 2nd transfer pressure sensor (PS50) doesn’t unblock (retracting) even after the lapse of a given period of time after the 2nd transfer pressure motor (M3) has started rotating during the 2nd image transfer roller is retracting.
-The 2nd transfer pressure sensor (PS50) doesn’t block (pressuring) even after the lapse of a given period of time after the 2nd transfer pressure motor (M3) has started rotating during the 2nd image transfer roller is pressuring.
Trouble isolation
Relevant electrical parts-2nd transfer pressure sensor (PS50)
-2nd transfer pressure motor (M3)
-Paper feed/transport drive board (PFTDB)
-Printer control board (PRCB)

(2)Procedure

StepActionControl signalLocation of electrical components
1Check the connector between M3-relay CN271A-PFTDB CN3 for proper connection and correct as necessary.
2Check the connector of M3 for proper drive coupling and correct as necessary.
3Check the connector between PS50-relay CN271B-PFTDB CN10 for proper connection and correct as necessary.
4PS50 I/O check, sensor checkPFTDB CN10-1 to 25 to 6-P
5M3 operation checkPFTDB CN3-9 (ON)5-P
6PFTDB ICP16 conduction check
7Replace M3 (Part# A0P0R75400)
8Replace PRCB (Part# A2X0H00102)

Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.