How Can We Help?

C2151 (bizhub C754/C654)

You are here:

Contents

Trouble typeSecondary transfer roller pressure welding alienation
Trouble codeC2151
RankB
Detection timing-The 2nd transfer pressure sensor (PS50) doesn’t unblock (retracting) even after the lapse of a given period of time after the 2nd transfer pressure motor (M3) has started rotating during the 2nd image transfer roller is retracting.
-The 2nd transfer pressure sensor (PS50) doesn’t block (pressuring) even after the lapse of a given period of time after the 2nd transfer pressure motor (M3) has started rotating during the 2nd image transfer roller is pressuring.
Trouble isolation
Relevant electrical parts-2nd transfer pressure sensor (PS50)
-2nd transfer pressure motor (M3)
-Paper feed/transport drive board (PFTDB)
-Printer control board (PRCB)

(2)Procedure

StepActionControl signalLocation of electrical components
1Check the connector between M3-relay CN271A-PFTDB CN3 for proper connection and correct as necessary.
2Check the connector of M3 for proper drive coupling and correct as necessary.
3Check the connector between PS50-relay CN271B-PFTDB CN10 for proper connection and correct as necessary.
4PS50 I/O check, sensor checkPFTDB CN10-1 to 25 to 6-P
5M3 operation checkPFTDB CN3-9 (ON)5-P
6PFTDB ICP16 conduction check
7Replace M3 (Part# A0P0R75400)
8Replace PRCB (Part# A2X0H00102)

Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.

K.3.7.2 (Link to the Field Service Manual)

Table of Contents