Trouble typeC2152: Transfer belt fault at initial position return
RankB
Trouble detection conditionThe 1st transfer pressure sensor (PS39) is unable to detect “switch from retraction to pressure” or “switch from pressure to retraction” within a given period time after the 1st transfer pressure clutch (CL5) has stared engagement during an initial position return.
Trouble isolation
Relevant electrical parts• Fusing motor (M3)
• 1st transfer pressure clutch (CL5)
• 1st transfer pressure sensor (PS39)
• Expansion control board (EXCB)
• MFP board (MFPB)

 Procedure

  1. Check the connector between M3-MFPB CN14E for proper connection and correct as necessary.
  2. Check the connector of M3 for proper drive coupling and correct as necessary.
  3. Check the connector between PS39-relay CN113-MFPB CN15E for proper connection and correct as necessary.
  4. Check the connector between CL5-relay CN118-EXCB CN8 for proper connection and correct as necessary.
  5. PS39 I/O check, sensor check
    • Control signal: MFPB CN15E<B>-10 (ON)
    • Location of electrical component: C658/C558 18-C, C458 21-C
  6. CL5 operation check
    • Control signal: EXCB CN8<A>-4 (CL5_REM)
    • Location of electrical component: 25-T
  7. M3 operation check
    • Control signal: MFPB CN14E-9 (REM), MFPB CN14E-12 (LOCK)
    • Location of electrical component: 2-C
  8. Replace M3. (Part# A2X0M10300)
  9. Replace EXCB. (Part# A79JH00500)
  10. MFPB F6E conduction check
  11. Replace MFPB. (C458 Part# A79MH02102 / C558 or C658 Part # A79JH02102)

NOTICE

Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.

K.3.12.1 (Link to the Field Service Manual)