C2153 (bizhub C658/C558/C458)

You are here:

Contents

Trouble typeC2153: Transfer belt spacing fault at K pressure switching
RankB
Trouble detection conditionThe 1st transfer pressure sensor (PS39) does not detect switch from pressure to retraction within a given period time after 1st transfer pressure clutch (CL5) has stared engagement.
Trouble isolation
Relevant electrical parts• Fusing motor (M3) 
• 1st transfer pressure clutch (CL5) 
• 1st transfer pressure sensor (PS39) 
• Expansion control board (EXCB) 
• MFP board (MFPB)

 Procedure

  1. Check the connector between M3-MFPB CN14E for proper connection and correct as necessary.
  2. Check the connector of M3 for proper drive coupling and correct as necessary.
  3. Check the connector between PS39-relay CN113-MFPB CN15E for proper connection and correct as necessary.
  4. Check the connector between CL5-relay CN118-EXCB CN8 for proper connection and correct as necessary.
  5. PS39 I/O check, sensor check
    • Control signal: MFPB CN15E<B>-10 (ON)
    • Location of electrical component: C658/C558 18-C, C458 21-C
  6. CL5 operation check
    • Control signal: EXCB CN8<A>-4 (CL5_REM)
    • Location of electrical component: 25-T
  7. M3 operation check
    • Control signal: MFPB CN14E-9 (REM), MFPB CN14E-12 (LOCK)
    • Location of electrical component: 2-C
  8. Replace M3. (Part# A2X0M10300)
  9. Replace EXCB. (Part# A79JH00500)
  10. MFPB F6E conduction check
  11. Replace MFPB. (C458 Part# A79MH02102 / C558 or C658 Part # A79JH02102)

NOTICE

Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.

K.3.12.1 (Link to the Field Service Manual)