C2153 (bizhub C658/C558/C458)
Contents
Trouble type | C2153: Transfer belt spacing fault at K pressure switching |
Rank | B |
Trouble detection condition | The 1st transfer pressure sensor (PS39) does not detect switch from pressure to retraction within a given period time after 1st transfer pressure clutch (CL5) has stared engagement. |
Trouble isolation | – |
Relevant electrical parts | • Fusing motor (M3) • 1st transfer pressure clutch (CL5) • 1st transfer pressure sensor (PS39) • Expansion control board (EXCB) • MFP board (MFPB) |
Procedure
- Check the connector between M3-MFPB CN14E for proper connection and correct as necessary.
- Check the connector of M3 for proper drive coupling and correct as necessary.
- Check the connector between PS39-relay CN113-MFPB CN15E for proper connection and correct as necessary.
- Check the connector between CL5-relay CN118-EXCB CN8 for proper connection and correct as necessary.
- PS39 I/O check, sensor check
- Control signal: MFPB CN15E<B>-10 (ON)
- Location of electrical component: C658/C558 18-C, C458 21-C
- CL5 operation check
- Control signal: EXCB CN8<A>-4 (CL5_REM)
- Location of electrical component: 25-T
- M3 operation check
- Control signal: MFPB CN14E-9 (REM), MFPB CN14E-12 (LOCK)
- Location of electrical component: 2-C
- Replace M3. (Part# A2X0M10300)
- Replace EXCB. (Part# A79JH00500)
- MFPB F6E conduction check
- Replace MFPB. (C458 Part# A79MH02102 / C558 or C658 Part # A79JH02102)
NOTICE
- Link to the wiring diagram (bizhub C658/C558/C458)
Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.
K.3.12.1 (Link to the Field Service Manual)