How Can We Help?

C2153 (bizhub C360i/C300i/C250i)

You are here:

Contents

Trouble typeC2153: Transfer belt spacing fault at K pressure switching
RankB
Trouble detection conditionC2153: The 1st transfer pressure sensor (PS39) does not detect “switch from pressure to retraction” within a given period time after 1st transfer pressure clutch (CL5) has stared engagement.
Trouble isolation
Relevant electrical parts• Fusing motor (M3)
• 1st transfer pressure clutch (CL5)
• 1st transfer pressure sensor (PS39)
• Expansion control board (EXCB)
• CPU board (CPUB)
• Base board (BASEB)

Procedure

  1. Check the connector between M3-BASEB CN19E for proper connection and correct as necessary.
  2. Check the connector of M3 for proper drive coupling and correct as necessary.
  3. Check the connector between PS39-relay CN113-BASEB CN13E for proper connection and correct as necessary.
  4. Check the connector between CL5-relay CN118-EXCB CN14EX for proper connection and correct as necessary.
  5. Check the connector between EXCB CN2EX-BASEB CN12E for proper connection and correct as necessary.
  6. Check CPUB for proper installation and correct as necessary.
  7. PS39 I/O check, sensor check
    • Control signal: BASEB CN13E-3 (ON)
    • Location of electrical component: 11-C
  8. CL5 load check
    • Check code: 24
    • Multi code: 1, 2, 102, 103, 106, 107
    • Control signal: EXCB CN14EX-9 (REM)
    • Location of electrical component: 6-P
  9. M3 load check
    • Check code: 45
    • Multi code: 1, 4, 5, 6
    • Control signal: BASEB CN19EA-6 to 10
    • Location of electrical component: 1-C
  10. Replace M3. (Part# AA2JM11000)
  11. Replace EXCB. (Part# AA2JH00500)
  12. Replace CPUB. (Part# AA2JH02N06)
  13. Replace BASEB. (Part# AA2JH02005)

Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.

L.3.8.1 (Link to the Field Service Manual)

Table of Contents