C2154 (bizhub C360i/C300i/C250i)
Contents
Trouble type | C2154: Transfer belt contact fault at all pressure switching |
Rank | B |
Trouble detection condition | C2154: The 1st transfer pressure sensor (PS39) does not detect “switch from retraction to pressure” within a given period time after 1st transfer pressure clutch (CL5) has stared engagement. |
Trouble isolation | – |
Relevant electrical parts | • Fusing motor (M3) • 1st transfer pressure clutch (CL5) • 1st transfer pressure sensor (PS39) • Expansion control board (EXCB) • CPU board (CPUB) • Base board (BASEB) |
Procedure
- Check the connector between M3-BASEB CN19E for proper connection and correct as necessary.
- Check the connector of M3 for proper drive coupling and correct as necessary.
- Check the connector between PS39-relay CN113-BASEB CN13E for proper connection and correct as necessary.
- Check the connector between CL5-relay CN118-EXCB CN14EX for proper connection and correct as necessary.
- Check the connector between EXCB CN2EX-BASEB CN12E for proper connection and correct as necessary.
- Check CPUB for proper installation and correct as necessary.
- PS39 I/O check, sensor check
- Control signal: BASEB CN13E-3 (ON)
- Location of electrical component: 11-C
- CL5 load check
- Check code: 24
- Multi code: 1, 2, 102, 103, 106, 107
- Control signal: EXCB CN14EX-9 (REM)
- Location of electrical component: 6-P
- M3 load check
- Check code: 45
- Multi code: 1, 4, 5, 6
- Control signal: BASEB CN19EA-6 to 10
- Location of electrical component: 1-C
- Replace M3. (Part# AA2JM11000)
- Replace EXCB. (Part# AA2JH00500)
- Replace CPUB. (Part# AA2JH02N06)
- Replace BASEB. (Part# AA2JH02005)
Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.
L.3.8.1 (Link to the Field Service Manual)