C2154 (bizhub C360i/C300i/C250i)

You are here:

Contents

Trouble typeC2154: Transfer belt contact fault at all pressure switching
RankB
Trouble detection conditionC2154: The 1st transfer pressure sensor (PS39) does not detect “switch from retraction to pressure” within a given period time after 1st transfer pressure clutch (CL5) has stared engagement.
Trouble isolation
Relevant electrical parts• Fusing motor (M3)
• 1st transfer pressure clutch (CL5)
• 1st transfer pressure sensor (PS39)
• Expansion control board (EXCB)
• CPU board (CPUB)
• Base board (BASEB)

Procedure

  1. Check the connector between M3-BASEB CN19E for proper connection and correct as necessary.
  2. Check the connector of M3 for proper drive coupling and correct as necessary.
  3. Check the connector between PS39-relay CN113-BASEB CN13E for proper connection and correct as necessary.
  4. Check the connector between CL5-relay CN118-EXCB CN14EX for proper connection and correct as necessary.
  5. Check the connector between EXCB CN2EX-BASEB CN12E for proper connection and correct as necessary.
  6. Check CPUB for proper installation and correct as necessary.
  7. PS39 I/O check, sensor check
    • Control signal: BASEB CN13E-3 (ON)
    • Location of electrical component: 11-C
  8. CL5 load check
    • Check code: 24
    • Multi code: 1, 2, 102, 103, 106, 107
    • Control signal: EXCB CN14EX-9 (REM)
    • Location of electrical component: 6-P
  9. M3 load check
    • Check code: 45
    • Multi code: 1, 4, 5, 6
    • Control signal: BASEB CN19EA-6 to 10
    • Location of electrical component: 1-C
  10. Replace M3. (Part# AA2JM11000)
  11. Replace EXCB. (Part# AA2JH00500)
  12. Replace CPUB. (Part# AA2JH02N06)
  13. Replace BASEB. (Part# AA2JH02005)

Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.

L.3.8.1 (Link to the Field Service Manual)