C2163 (bizhub 950i/850i)
Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.
Contents
Trouble type | C2163: Charge corona failure detection |
Rank | B |
Trouble detection condition | When a leak is detected continuously in a set period of time at the charge leak detection when the charge output is turned ON. |
Trouble isolation | – |
Relevant electrical parts | – Drum unit – High voltage unit/1 (HV1) – CPU board (CPUB) – Base board (BASEB) |
Procedure
- Check the drum unit for proper installation and correct as necessary.
- Check the connector between HV1 CN1-BASEB CN9E for proper connection and correct as necessary.
- Check CPUB for proper installation and correct as necessary.
- Replace the drum unit.
- Replace HV1.
- Replace CPUB.
- Replace BASEB.