C2152,C2153,C2155,C2157 (bizhub 950i/850i)
Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.
Contents
Trouble type | – C2152: Transfer belt fault at initial position return – C2153: Transfer belt spacing fault at K pressure switching – C2155: Transfer belt contact fault after K pressure established – C2157: Transfer belt spacing fault at all release switching |
Rank | B |
Trouble detection condition | – C2152: The 1st transfer pressure sensor/K (PS51) does not detect “switch from retraction to pressure” or “switch from pressure to retraction” within the set period of time during an initial position return. – C2153: The 1st transfer pressure sensor/K (PS51) does not detect “switch from retraction to pressure” within the set period of time after the pressure operation has stared. – C2155: The 1st transfer pressure sensor/K (PS51) is unblocked even after the set period of time has elapsed when the pressure operation is complete. – C2157: The 1st transfer pressure sensor/K (PS51) does not detect “switch from pressure to retraction” within a set period time after the retraction operation has started. Or the 1st transfer pressure sensor/K (PS51) is blocked even after the set period of time has elapsed when the retraction operation is complete. |
Trouble isolation | – |
Relevant electrical parts | – Transfer belt unit1st transfer pressure motor (M21) – 1st transfer pressure sensor/K (PS51) – CPU board (CPUB) – Base board (BASEB) |
Procedure
- Check the connector between M21-relay CN428-BASEB CN19E for proper connection and correct as necessary.
- Check the connector of M21 for proper drive coupling and correct as necessary.
- Check for proper sliding operation of the transfer belt unit transfer roller pressure gear and the proper roller operation. Correct as necessary.
- Check the connector between PS51-relay CN297-BASEB CN27E for proper connection and correct as necessary.
- Check CPUB for proper installation and correct as necessary.
- PS51 I/O check, sensor check
- Control signal: BASEB CN27E<A>-1 (ON)
- Location of electrical component: 14-C
- M21 load check
- Check code: 24
- Multi code: 1, 2, 3
- Control signal: BASEB CN19E-5 to 8
- Location of electrical component: 2-K
- Replace M21.
- Replace the transfer belt unit.
- Replace CPUB.
- BASEB F7E conduction check.
- Replace BASEB.