How Can We Help?

C2164 (bizhub C754/C654)

You are here:

Contents

Trouble typePC charge malfunction
Trouble codeC2164
RankB
Detection timingWhen electrostatic charge output is ON, electrostatic charge leak detection system continues to detect leaks for a predetermined period of time.
In this case, C2164 is displayed at the first detection and then after the trouble is reset, a leak IU identification process is executed. Then the trouble code corresponding to the IU color is displayed.
Trouble isolation
Relevant electrical parts-Imaging unit
-High voltage unit/1 (HV1)
-Printer control board (PRCB)

(2)Procedure

StepActionControl signalLocation of electrical components
1Check the imaging unit for proper connection and correct as necessary.
2Check the HV1 connector for proper connection and correct as necessary.
3Check the PRCB connector for proper connection and correct as necessary.
4Replace IU (C Part# A2X20KD, M Part# A2X20ED, Y Part# A2X208D)
5Replace HV1 (Part# A2X0M40700)
6Replace PRCB (Part# A2X0H00102)

Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.

K.3.7.4 (Link to the Field Service Manual)

Table of Contents