How Can We Help?

C2253 (bizhub C360i/C300i/C250i)

You are here:

Contents

Trouble typeC2253: PC motor failure to turn
RankB
Trouble detection conditionC2253: The control circuit detects motor failure to turn while the motor is turning.
Trouble isolation
Relevant electrical parts• PC motor (M2)
• CPU board (CPUB)
• Base board (BASEB)

Procedure

  1. Check the connector between M2-BASEB CN19E for proper connection and correct as necessary.
  2. Check the connector of M2 for proper drive coupling and correct as necessary.
  3. Check CPUB for proper installation and correct as necessary.
  4. M2 load check
    • Check code: 41
    • Multi code: 1, 4, 5
    • Control signal: BASEB CN19EB-1 to 5
    • Location of electrical component: 2-C
  5. Replace M2. (Part# AA2JM10200)
  6. Replace CPUB. (Part# AA2JH02N06)
  7. Replace BASEB. (Part# AA2JH02005)

Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.