How Can We Help?

C2253 (bizhub C658/C558/C458)

You are here:

Contents

Trouble typeC2253: PC motor’s failure to turn
RankB
Trouble detection conditionC2253: The motor lock signal remains HIGH for a predetermined continuous period of time while the motor is turning.
Trouble isolation
Relevant electrical parts• PC motor (M2)
• MFP board (MFPB)

 Procedure

  1. Check the connector between M2-MFPB CN23E for proper connection and correct as necessary.
  2. Check the connector of M2 for proper drive coupling and correct as necessary.
  3. M2 operation check
    • Control signal: MFPB CN23E-13 (REM), MFPB CN23E-16 (LOCK)
    • Location of electrical component: C658 3-C, C558 4-C, C458 6-C
  4. Replace M2. (Part# A782M10000)
  5. Replace MFPB. (C458Part# A79MH02102 / C558 or C658Part # A79JH02102)

NOTICE

Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.

K.3.12.2 (Link to the Field Service Manual)