C2254 (bizhub C658/C558/C458)
Contents
Trouble type | C2254: PC motor’s turning at abnormal timing |
Rank | B |
Trouble detection condition | The motor lock signal remains LOW for a predetermined continuous period of time while the motor remains stationary. |
Trouble isolation | – |
Relevant electrical parts | • PC motor (M2) • MFP board (MFPB) |
Procedure
- Check the connector between M2-MFPB CN23E for proper connection and correct as necessary.
- Check the connector of M2 for proper drive coupling and correct as necessary.
- M2 operation check
- Control signal: MFPB CN23E-13 (REM), MFPB CN23E-16 (LOCK)
- Location of electrical component: C658 3-C, C558 4-C, C458 6-C
- Replace M2. (Part# A782M10000)
- Replace MFPB. (C458Part# A79MH02102 / C558 or C658Part # A79JH02102)
NOTICE
- Link to the wiring diagram (bizhub C658/C558/C458)
Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.
K.3.12.2 (Link to the Field Service Manual)