Trouble typeC225B: PC motor/K failure to turn
RankB
Trouble detection conditionThe motor lock signal remains HIGH for a predetermined continuous period of time while the motor is turning.
Trouble isolation
Relevant electrical parts• Drum unit
• PC motor/K (M18)
• MFP board (MFPB)

 Procedure

  1. Check the connector between M18-MFPB CN10E for proper connection and correct as necessary.
  2. Check the connector of M18 for proper drive coupling and correct as necessary.
  3. M18 operation check
    • Control signal: MFPB CN10E-10 (REM), MFPB CN10E-13 (LOCK)
    • Location of electrical component: 5-K, 7-K
  4. Replace M18. (Part# A796M10100)
  5. Replace the drum unit. (Part# A8H40RD)
  6. MFPB F2E or F9E conduction check
  7. Replace MFPB. (Part# A796H02003)

NOTICE

Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.