How Can We Help?
C225B,C225C (bizhub 950i/850i)
Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.
Contents
Trouble type | C225B: PC motor/K failure to turn C225C: PC motor/K turning at abnormal timing |
Rank | B |
Trouble detection condition | C225B: The motor lock signal remains HIGH for a predetermined continuous period of time while the motor is turning. C225C: The motor lock signal remains LOW for a predetermined continuous period of time while the motor is stopping. |
Trouble isolation | – |
Relevant electrical parts | – Drum unit – PC motor/K (M18) – CPU board (CPUB) – Base board (BASEB) |
Procedure
- Check the connector between M18-BASEB CN10E for proper connection and correct as necessary.
- Check the connector of M18 for proper drive coupling and correct as necessary.
- Check CPUB for proper installation and correct as necessary.
- M28 load check
- Check code: 41
- Multi code: 5, 6, 7, 8
- Control signal: BASEB CN10E-10 (REM), BASEB CN10E-13 (LOCK)
- Location of electrical component: 6-K
- Replace M18.
- Replace the drum unit.
- Replace CPUB.
- BASEB F9E conduction check.
- Replace BASEB.