C2350 (bizhub 950i/850i)
Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.
Contents
Trouble type | C2350: Toner suction fan failure to turn |
Rank | B |
Trouble detection condition | The fan lock signal remains HIGH for a predetermined continuous period of time while the fan is turning. |
Trouble isolation | – |
Relevant electrical parts | – Toner suction fan (FM7) – CPU board (CPUB) – Base board (BASEB) |
Procedure
- Check the connector between FM7-relay CN326-BASEB CN24E for proper connection and correct as necessary.
- Check the fan for possible overload and correct as necessary.
- Check CPUB for proper installation and correct as necessary.
- FM7 load check
- Check code: 42
- Multi code: 1
- Control signal: BASEB CN24E-4 (DRIVE), BASEB CN24E-6 (LOCK)
- Location of electrical component: 1-K
- Replace FM7.
- Replace CPUB.
- BASEB F6E conduction check.
- Replace BASEB.