How Can We Help?

C2350 (bizhub C658/C558/C458)

You are here:

Contents

Trouble typeC2350: Toner suction fan’s failure to turn
RankB
Trouble detection conditionThe fan lock signal remains HIGH for a predetermined continuous period of time while the fan is turning.
Trouble isolation
Relevant electrical parts• Toner suction fan (FM11)
• MFP board (MFPB)

 Procedure

  1. Check the connector between FM11-relay CN62-MFPB CN31E for proper connection and correct as necessary.
  2. Check the fan for possible overload and correct as necessary.
  3. FM11 operation check
    • Control signal: MFPB CN31E<A>-12 (REM), MFPB CN31E<A>-14 (LOCK)
    • Location of electrical component: 24-J
  4. Replace FM11. (Part# 9313100072)
  5. Replace MFPB. (C458Part# A79MH02102 / C558 or C658Part # A79JH02102)

NOTICE

Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.

K.3.12.4 (Link to the Field Service Manual)

Table of Contents