C2355 (bizhub C658/C558/C458)
Contents
Trouble type | C2355: Transfer belt cleaner cooling fan’s failure to turn |
Rank | B |
Trouble detection condition | The fan lock signal remains HIGH for a predetermined continuous period of time while the fan is turning. |
Trouble isolation | – |
Relevant electrical parts | • Transfer belt cleaner cooling fan (FM2) • Expansion control board (EXCB) |
Procedure
- Check the connector between FM2-relay CN115-EXCB CN5 for proper connection and correct as necessary.
- Check the fan for possible overload and correct as necessary.
- FM2 operation check
- Control signal: EXCB CN5-1 (REM), EXCB CN5-3 (LOCK)
- Location of electrical component: 28-P
- Replace FM2. (Part# 4139M10000)
- MFPB F6E conduction check
- Replace EXCB. (Part# A79JH00500)
NOTICE
- Link to the wiring diagram (bizhub C658/C558/C458)
Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.
K.3.12.5 (Link to the Field Service Manual)