C2411 (bizhub C658/C558/C458)

You are here:

Contents

Trouble typeC2411: Developing unit/C new article release
RankB
Trouble detection conditionThe status with the new unit is not cleared after the new developing unit is set.
Trouble isolation
Relevant electrical parts• Developing unit/C,M,Y,K
• Front side board (FRB)
• MFP board (MFPB)

 Procedure

  1. Reinstall the developing unit.
  2. Check the connector between the developing unit-FRB CN13 (C2414), CN14 (C2411), CN15 (C2412), CN16 (C2413) for proper connection and correct as necessary.
  3. Check the connector between FRB CN1, CN3-MFPB CN4E, CN5E for proper connection and correct as necessary.
  4. Replace the developing unit. (C Part# A9C80KD, M Part# A9C80ED, Y Part# A9C808D , K Part# A9C803D)
  5. Replace FRB. (Part# A7PUH00500)
  6. Replace MFPB. (C458 Part# A79MH02102 / C558 or C658 Part # A79JH02102)

Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.

K.3.12.6 (Link to the Field Service Manual)