Contents
Trouble type | C2350: Toner suction fan failure to turn |
Rank | B |
Trouble detection condition | The fan lock signal remains HIGH for a predetermined continuous period of time while the fan is turning. |
Trouble isolation | – |
Relevant electrical parts | Toner suction fan (FM2)CPU board (CPUB)Base board (BASEB) |
Procedure
- Check the connector between FM2-relay CN10-BASEB CN24E for proper connection and correct as necessary.
- Check the fan for possible overload and correct as necessary.
- Check CPUB for proper installation and correct as necessary.
- FM2 load check
- Check code: 42
- Multi code: 3
- Control signal: BASEB CN24E-11 (REM), BASEB CN24E-13 (LOCK)
- Location of electrical component: 2-K
- Replace FM2.
- Replace CPUB.
- Replace BASEB.
(Link to the Field Service Manual)