How Can We Help?

C2353 (bizhub 958/808)

You are here:

Contents

Trouble typeC2353: IU cooling fan/out’s failure to turn
RankB
Trouble detection conditionThe fan lock signal remains HIGH for a predetermined continuous period of time while the fan is turning.
Trouble isolation
Relevant electrical parts• IU cooling fan /out (FM15)
• PH relay board (PHRYB)
• MFP board (MFPB)

 Procedure

  1. Check the connector between FM15-PHRYB CN5 for proper connection and correct as necessary.
  2. Check the fan for possible overload and correct as necessary.
  3. FM15 operation check
    • Control signal: PHRYB CN5-1 (DRIVE), PHRYB CN5-3 (LOCK)
    • Location of electrical component: 3-B
  4. Replace FM15. (Part# 9313110033)
  5. PHRYB F2 conduction check.
  6. Replace PHRYB. (Part# A796H00300)
  7. Replace MFPB. (Part# A796H02003)

NOTICE

Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.

K.3.8.10 (Link to the Field Service Manual)

Table of Contents