C2353 (bizhub 958/808)
Contents
Trouble type | C2353: IU cooling fan/out’s failure to turn |
Rank | B |
Trouble detection condition | The fan lock signal remains HIGH for a predetermined continuous period of time while the fan is turning. |
Trouble isolation | – |
Relevant electrical parts | • IU cooling fan /out (FM15) • PH relay board (PHRYB) • MFP board (MFPB) |
Procedure
- Check the connector between FM15-PHRYB CN5 for proper connection and correct as necessary.
- Check the fan for possible overload and correct as necessary.
- FM15 operation check
- Control signal: PHRYB CN5-1 (DRIVE), PHRYB CN5-3 (LOCK)
- Location of electrical component: 3-B
- Replace FM15. (Part# 9313110033)
- PHRYB F2 conduction check.
- Replace PHRYB. (Part# A796H00300)
- Replace MFPB. (Part# A796H02003)
NOTICE
- Link to the wiring diagram (bizhub 958/808/758, bizhub PRO 958)