How Can We Help?

C2356 (bizhub 958/808)

You are here:

Contents

Trouble typeC2356: IU cooling fan/in’s failure to turn
RankB
Trouble detection conditionThe fan lock signal remains HIGH for a predetermined continuous period of time while the fan is turning.
Trouble isolation
Relevant electrical parts• IU cooling fan /in (FM16)
• MFP board (MFPB)

 Procedure

  1. Check the connector between FM16-relay CN700-MFPB CN18E for proper connection and correct as necessary.
  2. Check the fan for possible overload and correct as necessary.
  3. FM16 operation check
    • Control signal: MFPB CN18E-9 (DRIVE), MFPB CN18E-11 (LOCK)
    • Location of electrical component: 15 to 16-K
  4. Replace FM16. (Part# 4556M10000)
  5. MFPB F7E conduction check
  6. Replace MFPB. (Part# A796H02003)

NOTICE

Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.

K.3.8.11 (Link to the Field Service Manual)

Table of Contents