C2551 (bizhub C4050i/C3350i)
Contents
Trouble type | C2551: Abnormally low toner density detected cyan TCR sensor |
Rank | B |
Trouble detection condition | When sampling data is determined in TC ratio calculation control, TCR sensor output is lower than a predetermined value for a predetermined number of times in a row even though there is toner in the toner cartridge. |
Trouble isolation | – |
Relevant electrical parts | • Imaging unit/C,M,Y,K • Toner supply motor/YM (M4) • Toner supply motor/CK (M5) • CPU board (CPUB) • Base board (BASEB) |
Procedure
- Perform image troubleshooting procedure if image density is low.
- Reinstall the imaging unit.
- Check the connector between the imaging unit/C-relay CN5-BASEB CN14E for proper connection and correct as necessary. (C2551)
- Check the connector between M4-BASEB CN13E for proper connection and correct as necessary.
- Check the connector between M5-BASEB CN13E for proper connection and correct as necessary.
- Check CPUB for proper installation and correct as necessary.
- M4, M5 operation check
- Control signal: BASEB CN13E-1 to 4 (M4), BASEB CN13E-5 to 8 (M5)
- Location of electrical component: 4-C
- Replace the corresponding imaging unit.
- Replace CPUB. (Part# A93EH01004)
- Replace BASEB. (Part# A93EH02007)
Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.
L.3.7.5 (Link to the Field Service Manual)