C2552 (bizhub C4050i/C3350i)
Contents
| Trouble type | C2552: Abnormally high toner density detected cyan TCR sensor | 
| Rank | B | 
| Trouble detection condition | TC ratio in the imaging unit, which is determined by toner replenishing amount control mechanism, is a predetermined value or more for a given number of times consecutively. | 
| Trouble isolation | – | 
| Relevant electrical parts | • Imaging unit/C,M,Y,K • CPU board (CPUB) • Base board (BASEB) | 
Procedure
- Reinstall the imaging unit.
- Check the connector between the imaging unit/C-relay CN5-EXCB CN14E for proper connection and correct as necessary. (C2552)
- Check CPUB for proper installation and correct as necessary.
- Replace the corresponding imaging unit.
- Replace CPUB. (Part# A93EH01004)
- Replace BASEB. (Part# A93EH02007)
Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.
L.3.7.6 (Link to the Field Service Manual)