How Can We Help?

C2563 (bizhub C4000i/C3300i)

You are here:

Contents

Trouble typeC2563: Yellow TCR sensor failure
RankB
Trouble detection condition• Alarm signals for each TCR sensor is detected more than the predetermined number of times. 
• This detection is used for detecting disconnection of TCR sensor connector.
Trouble isolation
Relevant electrical parts• Imaging unit/C,M,Y,K 
• CPU board (CPUB) 
• Base board (BASEB)

Procedure

  1. Reinstall the imaging unit.
  2. Check the connector between the imaging unit/Y-relay CN7-BASEB CN14E for proper connection and correct as necessary
  3. Check CPUB for proper installation and correct as necessary.
  4. Replace the corresponding imaging unit. (C Part# AAJV0HE, M Part# AAJV0CE, Y Part# AAJV06E , K Part# AAJV01E)
  5. Replace CPUB. (C4000i Part# Part# AAJRH01005 / C3300i Part# AAJTH01005)
  6. Replace BASEB. (Part# AAJRH02005)

Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.

L.3.7.8 (Link to the Field Service Manual)