C2564 (bizhub 750i)
Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.
Contents
Trouble type | C2564: Black TCR sensor failure |
Rank | B |
Trouble detection condition | -Alarm signals for TCR sensor is detected more than the predetermined number of times. -This detection is used for detecting disconnection of TCR sensor connector. |
Trouble isolation | – |
Relevant electrical parts | -Developing unit/K -Expansion control board (EXCB) -CPU board (CPUB) -Base board (BASEB) |
Procedure
- Reinstall the developing unit.
- Check the connector between the developing unit/K-relay CN252-relay CN25-EXCB CN4EX for proper connection and correct as necessary.
- Check the connector between EXCB CN1EX-BASEB CN11E for proper connection and correct as necessary.
- Check the connector between EXCB CN2EX-BASEB CN12E for proper connection and correct as necessary.
- Check CPUB for proper installation and correct as necessary.
- Replace the corresponding developing unit. (Part# ACV803D)
- Replace EXCB. (Part# AC74H00501)
- Replace CPUB. (Part# ACV7H02P02)
- Replace BASEB. (Part# ACV7H02101)