How Can We Help?

C2650 (bizhub 958/808)

You are here:

Contents

Trouble typeC2650: Main backup media access 1 error
RankC
Trouble detection condition• The re-written data, which has been read out, checked and founded as error, is read out again and found as error.
• The error was found when reading out the counter value.
• The main body detects that the back up board is not mounted.
Trouble isolation
Relevant electrical partsBack up board/1 (ERB/1)

 Procedure

  1. Check the connector between ERB-MFPB CN5E for proper connection and correct as necessary.
  2. Replace MFPB. (Part# A796H02003)
  3. Replace ERB. (ERB/1 Part# A796H00C00)
  4. If the above actions do not solve the problem, contact KM.

Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.

K.3.8.17 (Link to the Field Service Manual)