C2653 (bizhub C759/C659)
Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.
Contents
Trouble type | C2653: EEPROM access error (IU Y) |
Rank | C |
Trouble detection condition | -The re-written data, which has been read out, checked and founded as error, is read out again and found as error. -The error was found when reading out the counter value. |
Trouble isolation | – |
Relevant electrical parts | -Imaging unit/Y -PH relay board (PHRYB) -MFP board (MFPB) |
Procedure
- Clean the connection between the imaging unit and the machine if dirty.
- Reinstall the imaging unit.
- Check the connector between the imaging unit/Y-relay CN204-PHRYB CN4 for proper connection and correct as necessary.
- Check the connector between the imaging unit/M-relay CN207-PHRYB CN5 for proper connection and correct as necessary.
- Check the connector between the imaging unit/C-relay CN211-PHRYB CN5 for proper connection and correct as necessary.
- Replace the imaging unit. (Part# A9K708D)
- Replace PHRYB. (Part# A8JEH00301)
- Replace MFPB. (Part# A8JEH02002)
L.3.9.20 (Link to the Field Service Manual)