Trouble typeC265A: Main backup media wrongly installation
RankC
Trouble detection conditionThe ERB/1 and ERB/2 are mounted in a reverse direction.
Trouble isolation
Relevant electrical parts-Back up board/1 (ERB/1)
-Back up board/2 (ERB/2)

 Procedure

  1. Check to see if the ERB/1 and ERB/2 are mounted in a reverse direction.
  2. Check the type of the installed ERB and replace it if it is a wrong one.
  3. Replace ERB. (ERB/1 Part# A796H00C00 / ERB/2 Part# A7AHH00C00)

L.3.9.21 (Link to the Field Service Manual)