C265A (bizhub C759/C659)
Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.
Contents
Trouble type | C265A: Main backup media wrongly installation |
Rank | C |
Trouble detection condition | The ERB/1 and ERB/2 are mounted in a reverse direction. |
Trouble isolation | – |
Relevant electrical parts | -Back up board/1 (ERB/1) -Back up board/2 (ERB/2) |
Procedure
- Check to see if the ERB/1 and ERB/2 are mounted in a reverse direction.
- Check the type of the installed ERB and replace it if it is a wrong one.
- Replace ERB. (ERB/1 Part# A796H00C00 / ERB/2 Part# A7AHH00C00)
L.3.9.21 (Link to the Field Service Manual)