How Can We Help?

C2A14 (bizhub 554e/454e)

You are here:

)Contents

Trouble typeDrum unit new release failure
Trouble codeC2A14
RankB
Detection timingThe status with the new unit is not cleared after the new drum unit is set.
Trouble isolation
Relevant electrical parts• Drum unit
• Front side board (FRB)
• Printer control board (PRCB)

 (2)Procedure

StepActionControl signalLocation of electrical components
1Clean the connection between the drum unit and the developing unit if dirty
2Reinstall drum unit
3Check the connector between drum unit-FRB CN12 for proper connection and correct as necessary.
4Check the connector between FRB CN1, CN3-PRCB CN7, CN9 for proper connection and correct as necessary.
5Replace the drum unit (Part# A2XN0RD)
6Replace FRB (Part# A61FH00500)
7Replace PRCB (554e Part# A61EH00101 / 454e Part# A61DH00101)
  • Link to the layout drawings for related parts by each trouble code (S.63. C2A14)

Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.

K.3.7.9 (Link to the Field Service Manual)

Table of Contents