Trouble type Drum unit new release failure
Trouble code C2A14
Rank B
Detection timing The status with the new unit is not cleared after the new drum unit is set.
Trouble isolation
Relevant electrical parts• Drum unit
• Front side board (FRB)
• Printer control board (PRCB)

  (2)Procedure

Step Action Control signal Location of electrical components
1 Clean the connection between the drum unit and the developing unit if dirty
2 Reinstall drum unit
3 Check the connector between drum unit-FRB CN12 for proper connection and correct as necessary.
4 Check the connector between FRB CN1, CN3-PRCB CN7, CN9 for proper connection and correct as necessary.
5 Replace the drum unitDrum 554e/454e (Part# A2XN0RD)
6 Replace FRBFRB (Part# A61FH00500)
7 Replace PRCBPRCB (Part# 554e A61DH00101 454e A61EH00101)
  • Link to the layout drawings for related parts by each trouble code (S.63. C2A14)