C2A24 (bizhub 368e/308e)
Contents
Trouble type | C2A24: Toner cartridge/K new release failure |
Rank | C |
Trouble detection condition | The status with the new unit is not cleared after the new toner cartridge is set. |
Trouble isolation | – |
Relevant electrical parts | • Toner cartridge • MFP board (MFPB) |
Procedure
- Clean the connection between the toner cartridge and the main body if dirty.
- Check the connector between the toner cartridge-relay CN79-MFPB CN35E for proper connection and correct as necessary.
- Reinstall the toner cartridge.
- Check the harness for proper connection and correct as necessary.
- Replace the toner cartridge. (Part# AAJ6030)
- MFPB ICP12E conduction check
- Replace MFPB. (Part# AA6VH02101)
Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.
L.3.9.10 (Link to the Field Service Manual)