Trouble type Toner cartridge new release failure
Trouble code C2A24
Rank C
Detection timing The status with the new cartridge is not cleared after the new toner cartridge is set.
Trouble isolation
Relevant electrical parts• Toner cartridge
• Extension control board (EXCB)
• Printer control board (PRCB)

  (2)Procedure

Step Action Control signal Location of electrical components
1 Clean the connection between the toner cartridge and the machine if dirty.
2 Check the connector between toner cartridge-relay CN79-EXCB CN4 for proper connection and correct as necessary.

3 Reinstall the toner cartridge
4 Check the harness for proper connection and correct as necessary.
5 Check the connector between EXCB CN2-PRCB CN11 for proper connection and correct as necessary.
6 Replace the toner cartridge (Part# A33K031)
7 Replace PRCBPRCB (Part# 554e A61DH00101 454e A61EH00101)
  • Link to the layout drawings for related parts by each trouble code (S.64. C2A24)